100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V

100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V
$17.99
Ex Tax: $17.99
  • Stock: In Stock
  • Model: MZ005122
  • SKU: MZ005122
  • UPC: 669424573035

100A 22kW AC Multi-Function Power Monitoring Meter Module 80–260V

Core Brief

This AC power monitor module supports 80–260 V wide voltage, max 100 A / 22 kW load, with 1.0 measurement accuracy. Large LCD screen simultaneously displays voltage, current, active power and total energy. Built overload flash alarm and power-off memory, self-powered from grid without extra power supply. Matched CT current transformer included, widely used for PV energy monitoring, appliance aging test, laboratory equipment, household energy statistics and cabinet power monitoring.

Core Key Features

  • 1% High Measurement Precision Stable data reading for resistive & inductive loads.
  • 4-in-1 Simultaneous Display: Voltage / Current / Active Power / Total Energy.
  • Overload Flash Warning: Backlight flickers automatically when exceeding set power threshold.
  • Custom Alarm Threshold Setting Function for different load limits.
  • Power-Off Data Memory: Saved energy data won’t be cleared after power cut.
  • Grid Self-Powered Design, no external DC adapter required.
  • 45–65 Hz wide frequency compatibility fits global household grid.
  • Comes with matching CT current transformer for easy wiring.

Full Technical Specification Table

Model SKUMZ005122
Rated Max Current100 A
Max Active Power22 kW
Working Voltage RangeAC 80 V ~ 260 V
Frequency Support45 Hz ~ 65 Hz
Measurement AccuracyClass 1 (±1% error)
LCD Screen Size51 × 30 mm
Display ParametersV, A, Active Power, Cumulative Energy
Alarm ModeBacklight Flash Overload Reminder
Power SupplyDirect grid power supply, no external power needed

Display Format Standard

  • Power: 0.0 ~ 999.9 W (below 1kW) / 1.0 ~ 9.9 kW (1–10kW) / 10.0 ~ 22.0 kW (over 10kW)
  • Energy: 0 ~ 9999 Wh (below 10kWh) / 10 ~ 9999 kWh (over 10kWh)
  • Voltage: 80 ~ 260 V real-time reading
  • Current: 0.00 ~ 99.99 A real-time reading

Common Reading Difference Explanation (U*I ≠ Display Power)

Displayed reading is Active Power (P, unit W), while U×I is Apparent Power (S, VA). Formula: P = U × I × cosφ (power factor). 1. Pure resistive loads (heater, incandescent lamp): cosφ ≈ 1, P close to U×I; 2. Inductive / capacitive loads (refrigerator, TV, PC): cosφ 0~1, active power will be lower than U×I calculation result.

Application Scenarios

  • PV solar energy storage power statistics
  • Home / rental house electricity consumption monitoring
  • Laboratory appliance aging test bench
  • Industrial cabinet & equipment power monitoring
  • DIY electronic projects & repair workshop testing

Safety & Wiring Reminders

  1. Indoor use only; strictly prohibited for outdoor wet environment.
  2. Do not exceed the maximum 100 A / 22 kW rated load to avoid burnout.
  3. Follow standard wiring sequence strictly; wrong wiring causes module damage.
  4. Cut off grid power before wiring installation.
  5. Regularly check CT transformer for loose contact during long-time operation.

Package Contents

  • 1 × 100A AC Multi-Function Power Monitor Meter Module
  • 1 × Matching CT Current Transformer
  • 1 × Multilingual Operation & Wiring Manual

Frequently Asked Questions

Q1 Why displayed power is lower than voltage × current calculation?

A1 The meter measures active power with power factor correction; inductive loads reduce active power value.

Q2 Does this meter need an external power adapter?

A1 No, it takes power directly from the AC grid circuit.

Q3 Will energy data be lost after power failure?

A1 Built power-off memory function stores cumulative energy permanently.

Q4 What’s the maximum supported load power?

A1 Max 22 kW / 100 A resistive AC load.

Geekcreitreg-100A-22000W-Power-Monitor-Module-AC-Meter-Panel-45-65Hz-Test-Voltage-AC-80-260V-983057-1,Geekcreitreg-100A-22000W-Power-Monitor-Module-AC-Meter-Panel-45-65Hz-Test-Voltage-AC-80-260V-983057-2,Geekcreitreg-100A-22000W-Power-Monitor-Module-AC-Meter-Panel-45-65Hz-Test-Voltage-AC-80-260V-983057-3,Geekcreitreg-100A-22000W-Power-Monitor-Module-AC-Meter-Panel-45-65Hz-Test-Voltage-AC-80-260V-983057-4,Geekcreitreg-100A-22000W-Power-Monitor-Module-AC-Meter-Panel-45-65Hz-Test-Voltage-AC-80-260V-983057-5

Write a review

Note: HTML is not translated!
Bad Good